Home  /   Contact us  /  FAQ  /  Site Map  /  繁體中文        
Company Products New Products Distributor News Service & Support
 
 
AC-DC ITE Power Module
AC-DC Household Power Module
AC-DC Medical Power Module
AC-DC Medical Swiching Power Supply
AC-DC ITE Switching Power Supply
AC-DC ITE Full Brick
DC-DC Converter
Safety Listing
 
      AC-DC ITE Power Module  
   
 
Watts Series Picture I/P Voltage Safety Features  Isolation:3000VAC
  Operating Temperature:
          -40°C~+70°C
Down Load AOD10 Series SPC.
    Household Power Module 90 ~ 264 VAC EN 60950, EN 60335, CE, 回  •Maximum No-Load Watts < 0.1W
 •Low Ripple and Noise
 •Isolation Class II
 •3-Year Product Warranty
10 W AOD10 O/P Voltage Dimension
Single:5,12,15,24   37.0 x 27.5 x 20.0 mm
  1.46 x 1.08 x 0.79 inches
 
   
 
Watts Series Picture I/P Voltage Safety Features  Isolation:4000VAC or
                 5656VDC
  Operating Temperature:
          -40°C~+80°C Down Load MFC15 Series SPC.
    ITE Medical Power Module 90 ~ 264 VAC EN 60950, EN60601, CE, CB  •Low Standby <0.1W
 •Small Size
 •Low Ripple and Noise
 •Isolation Class II
15 W MFC15 O/P Voltage Dimension
Single:5,9,12
          15,24
  52.5 x 27.5 x 23.5 mm
  2.07 x 1.08 x 0.93 Inches
 
   
 
Watts Series Picture I/P Voltage Safety Features  Isolation:3000VAC
  Operating Temperature:
          -40°C~+70°C
Down Load AFC20H Series SPC.
    Household Power Module 90 ~ 305 VAC EN 60950, CE, 回  •Low Standby <0.1W
 •Low Ripple and Noise
 •Small Size as AFCN with 25Watt
 •Isolation Class II
 •3-Year Product Warranty
25 W AFC20H O/P Voltage Dimension
Single:5,12,15,24   52.5 x 27.5 x 23.5 mm
  2.07 x 1.08 x 0.93 Inches
 
   
 
Watts Series Picture I/P Voltage Safety Features  Isolation:4000VAC or
                 5656VDC
  Operating Temperature:
          -40°C~+80°C Down Load MZC20 Series SPC.
    ITE Medical Power Module 90 ~ 264 VAC EN 60950, EN60601, CE, CB  •Low Standby <0.1W
 •Small Size
 •Low Ripple and Noise
 •Isolation Class II
20 W MZC20 O/P Voltage Dimension
Single:12,24   52.5 x 27.5 x 23.5 mm
  2.07 x 1.08 x 0.93 Inches
 
   
 
Watts Series Picture I/P Voltage Safety Features  Isolation:3000VAC
  Operating Temperature:
          -40°C~+70°C
Down Load AFD25 Series SPC.
    Household Power Module 90 ~ 264 VAC EN 60950, EN 60335, CE, 回  •Low Standby <0.1W
 •Low Ripple and Noise
 •Small Size as AFCN with 25Watt
 •Isolation Class II
 •3-Year Product Warranty
25 W AFD25 O/P Voltage Dimension
Single:5,12,15,24   52.5 x 27.5 x 23.5 mm
  2.07 x 1.08 x 0.93 Inches
 
   
 
Watts Series Picture I/P Voltage Safety Features  Isolation:4000VAC or
                 5656VDC
  Operating Temperature:
          -40°C~+80°C Down Load MTC30 Series SPC.
    ITE Medical Power Module 90 ~ 264 VAC EN 60950, EN60601, CE, CB  •Low Standby <0.1W
 •Small Size
 •Low Ripple and Noise
 •Isolation Class II
30 W MTC30 O/P Voltage Dimension
Single:5,12,15,24   64.1 x 45.6x 23.5 mm
  2.52 x 1.8 x 0.93 Inches
 
   
 
Watts Series Picture I/P Voltage Safety Features  Isolation:4000VAC or
                 5656VDC
  Operating Temperature:
          -40°C~+80°C Down Load MSC60 Series SPC.
    ITE Medical Power Module 90 ~ 264 VAC EN 60950, EN60601, CE, CB  •Low Standby <0.1W
 •Small Size
 •Low Ripple and Noise
 •Isolation Class II
60 W MSC60 O/P Voltage Dimension
Single:5,9,12
          15,24
  89.0 x 63.5 x 27.0 mm
  3.5 x 2.5 x 1.06Inches
 
   
 
Watts Series Picture I/P Voltage Safety Features
  Isolation:4000VAC or
                 5656VDC

  Operating Temperature:
          -30°C~+70°C

Down Load MQC100 Series SPC.
    ITE Medical Power Module 90 ~ 264 VAC EN 60950, EN60601, CE  •4000VAC Input to Output
     2MOPP Insulation
 •High Efficiency up to 93.5%
 •With P.F.C. Function >0.9
 •<0.5W No Load Input Power
 •Protections: Over Load /
    Over Voltage / Over Temperature
     / Short Circuit
 •EMI for Both Class I (with FG)
    and Class II (without FG)     Configuration
 •Suitable for BF Application with
    Appropriate System
    Consideration
 •UL / IEC / EN 60601 3.1rd
    & Edition UL / IEC / EN 60950
    AM2 Safety Approvals
100 W MQC100 O/P Voltage Dimension
Single:12,15,24
          48
  109.0 x 58.5 x 34.1 mm
  4.3 x 2.3 x 1.34 Inches
 
 
   
 
Watts Series Picture I/P Voltage Safety Features
  Isolation:4000VAC or
                 5656VDC

  Operating Temperature:
          -30°C~+70°C

Down Load MQC150 Series SPC.
    ITE Medical Power Module 90 ~ 264 VAC EN 60950, EN60601, CE  •4000VAC Input to Output
     2MOPP Insulation
 •High Efficiency up to 93.5%
 •With P.F.C. Function >0.9
 •<0.5W No Load Input Power
 •Protections: Over Load /
    Over Voltage / Over Temperature
     / Short Circuit
 •EMI for Both Class I (with FG)
    and Class II (without FG)     Configuration
 •Suitable for BF Application with
    Appropriate System
    Consideration
 •UL / IEC / EN 60601 3.1rd
    & Edition UL / IEC / EN 60950
    AM2 Safety Approvals
150 W MQC150 O/P Voltage Dimension
Single:12,15,24
          48
  109.0 x 58.5 x 34.1 mm
  4.3 x 2.3 x 1.34 Inches
 
 
   
      AC-DC Household Power Module  
   
 
Watts Series Picture I/P Voltage Safety Features  Isolation:3000VAC
  Operating Temperature:
          -40°C~+70°C
Down Load AOD10 Series SPC.
    AC-DC ITE Power Module 90 ~ 264 VAC EN 60950, EN 60335, CE, 回  •Maximum No-Load Watts < 0.1W
 •Low Ripple and Noise
 •Isolation Class II
 •3-Year Product Warranty
10 W AOD10 O/P Voltage Dimension
Single:5,12,15,24   37.0 x 27.5 x 20.0 mm
  1.46 x 1.08 x 0.79 inches
 
Watts Series Picture I/P Voltage Safety Features  Isolation:3000VAC
  Operating Temperature:
          -40°C~+70°C
Down Load AFD25 Series SPC.
    AC-DC ITE Power Module 90 ~ 264 VAC EN 60950, EN 60335, CE, 回  •Low Standby <0.1W
 •Low Ripple and Noise
 •Small Size as AFCN with 25Watt
 •Isolation Class II
 •3-Year Product Warranty
25 W AFD25 O/P Voltage Dimension
Single:5,12,15,24   52.5 x 27.5 x 23.5 mm
  2.07 x 1.08 x 0.93 Inches
 
   
      AC-DC ITE Medical Power Module  
   
 
Watts Series Picture I/P Voltage Safety Features  Isolation:4000VAC or
                 5656VDC
  Operating Temperature:
          -40°C~+80°C Down Load MFC15 Series SPC.
    AC-DC ITE Power Module 90 ~ 264 VAC EN 60950, EN60601, CE, CB  •Low Standby <0.1W
 •Small Size
 •Low Ripple and Noise
 •Isolation Class II
15 W MFC15 O/P Voltage Dimension
Single:5,9,12
          15,24
  52.5 x 27.5 x 23.5 mm
  2.07 x 1.08 x 0.93 Inches
 
   
 
Watts Series Picture I/P Voltage Safety Features  Isolation:4000VAC or
                 5656VDC
  Operating Temperature:
          -40°C~+80°C Down Load MZC20 Series SPC.
    AC-DC ITE Power Module 90 ~ 264 VAC EN 60950, EN60601, CE, CB  •Low Standby <0.1W
 •Small Size
 •Low Ripple and Noise
 •Isolation Class II
20 W MZC20 O/P Voltage Dimension
Single:12,24   52.5 x 27.5 x 23.5 mm
  2.07 x 1.08 x 0.93 Inches
 
   
 
Watts Series Picture I/P Voltage Safety Features  Isolation:4000VAC or
                 5656VDC
  Operating Temperature:
          -40°C~+80°C Down Load MTC30 Series SPC.
    AC-DC ITE Power Module 90 ~ 264 VAC EN 60950, EN60601, CE, CB  •Low Standby <0.1W
 •Small Size
 •Low Ripple and Noise
 •Isolation Class II
30 W MTC30 O/P Voltage Dimension
Single:5,12,15,24   64.1 x 45.6x 23.5 mm
  2.52 x 1.8 x 0.93 Inches
 
   
 
Watts Series Picture I/P Voltage Safety Features  Isolation:4000VAC or
                 5656VDC
  Operating Temperature:
          -40°C~+80°C Down Load MSC60 Series SPC.
    AC-DC ITE Power Module 90 ~ 264 VAC EN 60950, EN60601, CE, CB  •Low Standby <0.1W
 •Small Size
 •Low Ripple and Noise
 •Isolation Class II
60 W MSC60 O/P Voltage Dimension
Single:5,9,12
          15,24
  89.0 x 63.5 x 27.0 mm
  3.5 x 2.5 x 1.06Inches
 
   
 
Watts Series Picture I/P Voltage Safety Features
  Isolation:4000VAC or
                 5656VDC

  Operating Temperature:
          -30°C~+70°C

Down Load MQCS100 Series SPC.
    Medical Power Module 90 ~ 264 VAC EN 60950, EN60601, CE  •4000VAC Input to Output
     2MOPP Insulation
 •High Efficiency up to 93.5%
 •With P.F.C. Function >0.9
 •<0.5W No Load Input Power
 •Protections: Over Load /
    Over Voltage / Over Temperature
     / Short Circuit
 •EMI for Both Class I (with FG)
    and Class II (without FG)     Configuration
 •Suitable for BF Application with
    Appropriate System
    Consideration
 •UL / IEC / EN 60601 3.1rd
    Safety Approvals
100 W MQCS100 O/P Voltage Dimension
Single:12,24,48   83.9 x 58.5 x 34.5 mm
  3.3 x 2.3 x 1.58 Inches
 
 
   
 
Watts Series Picture I/P Voltage Safety Features
  Isolation:4000VAC or
                 5656VDC

  Operating Temperature:
          -30°C~+70°C

Down Load MQC100 Series SPC.
    AC-DC ITE Power Module 90 ~ 264 VAC EN 60950, EN60601, CE  •4000VAC Input to Output
     2MOPP Insulation
 •High Efficiency up to 93.5%
 •With P.F.C. Function >0.9
 •<0.5W No Load Input Power
 •Protections: Over Load /
    Over Voltage / Over Temperature
     / Short Circuit
 •EMI for Both Class I (with FG)
    and Class II (without FG)     Configuration
 •Suitable for BF Application with
    Appropriate System
    Consideration
 •UL / IEC / EN 60601 3.1rd
    & Edition UL / IEC / EN 60950
    AM2 Safety Approvals
100 W MQC100 O/P Voltage Dimension
Single:12,15,24
          48
  109.0 x 58.5 x 34.1 mm
  4.3 x 2.3 x 1.34 Inches
 
 
   
 
Watts Series Picture I/P Voltage Safety Features
  Isolation:4000VAC or
                 5656VDC

  Operating Temperature:
          -30°C~+70°C

Down Load MQC150 Series SPC.
    AC-DC ITE Power Module 90 ~ 264 VAC EN 60950, EN60601, CE  •4000VAC Input to Output
     2MOPP Insulation
 •High Efficiency up to 93.5%
 •With P.F.C. Function >0.9
 •<0.5W No Load Input Power
 •Protections: Over Load /
    Over Voltage / Over Temperature
     / Short Circuit
 •EMI for Both Class I (with FG)
    and Class II (without FG)     Configuration
 •Suitable for BF Application with
    Appropriate System
    Consideration
 •UL / IEC / EN 60601 3.1rd
    & Edition UL / IEC / EN 60950
    AM2 Safety Approvals
150 W MQC150 O/P Voltage Dimension
Single:12,15,24
          48
  109.0 x 58.5 x 34.1 mm
  4.3 x 2.3 x 1.34 Inches
 
 
   
      AC-DC Medical Swiching Power Supply  
   
 
Watts Series Picture I/P Voltage Safety Features   Isolation:4000VAC or
                 5656VDC
  Operating Temperature:
          -30°C~+70°C   
    Medical Swiching Power 90 ~ 264 VAC EN 60950, EN60601, CE  •Open Frame, Enclosed and
     U Bracket Design
 •4000VAC Input to Output
     2MOPP Insulation
 •100 Watts and 120Watt
     with 10CFM Forced Air
 •High Efficiency up to 93%
 •With P.F.C. Function >0.9
 •<0.3W No Load Input Power
 •EMI for Both Class I (with PE)
    and Class II (without PE)
    Configuration
 •Suitable for BF Application with
    Appropriate System
    Consideration
 •UL / IEC / EN 60601 3.1rd
    Safety Approvals
  O/P Voltage Dimension
120 W MQF120O Single:12,24,48   Open Frame:  
  76.2 x 58.8 x 30.1mm
  3.0 x 2.0 x 1.18 Inches
    MQF120O: Down Load MQF120O Series SPC.
MQF120E   Enclosed:  
  80.0 x 59.7 x 38.0mm
  3.15 x 2.35 x 1.5 Inches
    MQF120E: Down Load MQF120E Series SPC.
MQF120U   U Bracket:  
  80.0 x 59.7 x 38.0mm
  3.15 x 2.35 x 1.5 Inches
    MQF120U: Down Load MQF120U Series SPC.
       
 
   
 
Watts Series Picture I/P Voltage Safety Features   Isolation:4000VAC or
                 5656VDC
  Operating Temperature:
          -30°C~+70°C   
    Medical Swiching Power 90 ~ 264 VAC EN 60950, EN60601, CE  •Open Frame, Enclosed and
     U Bracket Design
 •4000VAC Input to Output
     2MOPP Insulation
 •160 Watts and 240Watt
     with 10CFM Forced Air
 •High Efficiency up to 93.5%
 •With P.F.C. Function >0.9
 •<0.5W No Load Input Power
 •EMI for Both Class I (with PE)
    and Class II (without PE)
    Configuration
 •Suitable for BF Application with
    Appropriate System
    Consideration
 •UL / IEC / EN 60601 3.1rd
    & Edition UL / IEC / EN 60950
    AM2 Safety Approvals
    ITE Swiching Power O/P Voltage Dimension
240 W MQF240O Single:12,15,24
          48
  Open Frame:  
  103.9 x 52.0 x 27.6 mm
  4.1 x 2.05 x 1.089 Inches
    MQF240O: Down Load MQF240O Series SPC.
MQF240E   Enclosed:  
  104.0 x 62.0 x 50.5 mm
  4.1 x 2.44 x 1.99 Inches
    MQF240E: Down Load MQF240E Series SPC.
MQF240U   U Bracket:  
  104.0 x 62.0 x 39.2 mm
  4.1 x 2.44 x 1.544 Inches
    MQF240U: Down Load MQF240U Series SPC.
       
 
   
 
Watts Series Picture I/P Voltage Safety Features   Isolation:4000VAC or
                 5656VDC
  Operating Temperature:
          -30°C~+70°C   
    Medical Swiching Power 90 ~ 264 VAC EN 60950, EN60601, CE  •Open Frame, Enclosed and
     U Bracket Design
 •4000VAC Input to Output
     2MOPP Insulation
 •240 Watts and 500Watt
     with 30CFM Forced Air
 •High Efficiency up to 93%
 •With P.F.C. Function >0.94
 •Remote ON/OFF Function
 •EMI for Both Class I (with PE)
    and Class II (without PE)
    Configuration
 •Suitable for BF Application with
    Appropriate System
    Consideration
 •UL / IEC / EN 60601 3.1rd
    & Edition UL / IEC / EN 60950
    AM2 Safety Approvals
    ITE Swiching Power O/P Voltage Dimension
500 W MQF500O Single:12,15,24
          48
  Open Frame:  
  127.8 x 76.2 x 35.0mm
  5.03 x 3.0 x 1.38 Inches
    MQF500O: Down Load MQF500O Series SPC.
MQF500E   Enclosed:  
  139.7 x 82.55 x 62.9mm
  5.5 x 3.25 x 2.48Inches
    MQF500E: Down Load MQF500E Series SPC.
MQF500U   U Bracket:  
  139.7 x 82.55 x 42.1mm
  5.5 x 3.25 x 1.66 Inches
    MQF500U: Down Load MQF500U Series SPC.
       
 
   
      AC-DC ITE Swiching Power Supply  
   
 
Watts Series Picture I/P Voltage Safety Features   Isolation:4000VAC or
                 5656VDC
  Operating Temperature:
          -30°C~+70°C   
    Medical Swiching Power 90 ~ 264 VAC EN 60950, EN60601, CE  •Open Frame, Enclosed and
     U Bracket Design
 •4000VAC Input to Output
     2MOPP Insulation
 •160 Watts and 240Watt
     with 10CFM Forced Air
 •High Efficiency up to 93.5%
 •With P.F.C. Function >0.9
 •<0.5W No Load Input Power
 •EMI for Both Class I (with PE)
    and Class II (without PE)
    Configuration
 •Suitable for BF Application with
    Appropriate System
    Consideration
 •UL / IEC / EN 60601 3.1rd
    & Edition UL / IEC / EN 60950
    AM2 Safety Approvals
    ITE Swiching Power O/P Voltage Dimension
240 W MQF240O Single:12,15,24
          48
  Open Frame:  
  103.9 x 52.0 x 27.6 mm
  4.1 x 2.05 x 1.089 Inches
    MQF240O: Down Load MQF240O Series SPC.
MQF240E   Enclosed:  
  104.0 x 62.0 x 50.5 mm
  4.1 x 2.44 x 1.99 Inches
    MQF240E: Down Load MQF240E Series SPC.
MQF240U   U Bracket:  
  104.0 x 62.0 x 39.2 mm
  4.1 x 2.44 x 1.544 Inches
    MQF240U: Down Load MQF240U Series SPC.
       
 
   
 
Watts Series Picture I/P Voltage Safety Features   Isolation:3000VAC
  Operating Temperature:
          -40°C~+65°C   
    ITE Swiching Power 90 ~ 264 VAC EN 60950, CE  •Enclosed and U Bracket Design
 •Over Current Protection
 •Over Voltage Protection
 •Over Temperature Protection
 •Short Circuit Protection
 •300W Convection with
     18CFM FAN
 •With P.F.C. Function >0.9
 
  O/P Voltage Dimension
300 W ABR300U Single:12,24,28,
48
  U Bracket:  
  150.0 x 106.0 x 36.0mm
  6.0 x 4.18x 1.481 Inches
    ABR300U: Down Load ABR300U Series SPC.
ABR300UC     ABR300UC: Down Load ABR300UC Series SPC.
 
   
 
Watts Series Picture I/P Voltage Safety Features   Isolation:4000VAC or
                 5656VDC
  Operating Temperature:
          -30°C~+70°C   
    Medical Swiching Power 90 ~ 264 VAC EN 60950, EN60601, CE  •Open Frame, Enclosed and
     U Bracket Design
 •4000VAC Input to Output
     2MOPP Insulation
 •240 Watts and 500Watt
     with 30CFM Forced Air
 •High Efficiency up to 93%
 •With P.F.C. Function >0.94
 •Remote ON/OFF Function
 •EMI for Both Class I (with PE)
    and Class II (without PE)
    Configuration
 •Suitable for BF Application with
    Appropriate System
    Consideration
 •UL / IEC / EN 60601 3.1rd
    & Edition UL / IEC / EN 60950
    AM2 Safety Approvals
    ITE Swiching Power O/P Voltage Dimension
500 W MQF500O Single:12,15,24
          48
  Open Frame:  
  127.8 x 76.2 x 35.0mm
  5.03 x 3.0 x 1.38 Inches
    MQF500O: Down Load MQF500O Series SPC.
MQF500E   Enclosed:  
  139.7 x 82.55 x 62.9mm
  5.5 x 3.25 x 2.48Inches
    MQF500E: Down Load MQF500E Series SPC.
MQF500U   U Bracket:  
  139.7 x 82.55 x 42.1mm
  5.5 x 3.25 x 1.66 Inches
    MQF500U: Down Load MQF500U Series SPC.
       
 
   
      AC-DC ITE Full Brick  
   
 
Watts Series Picture I/P Voltage Safety Features  Isolation:3000VAC
  Operating Temperature:
          -40°C~+70°C
Down Load ABR300 Series SPC.
    90 ~ 264 VAC EN 60950, CE •Full Brick Size with Base Plate
 •Over Current Protection
 •Over Voltage Protection
 •Over Temperature Protection
 •Short Circuit Protection
 •Remote Sense
300 W ABR300 O/P Voltage Dimension
Single:12,24,28,
48
  117.3 x 62.5 x 12.7mm
  4.62 x 2.42 x 0.5 inches
 
 
   
      DC-DC Converter  
   
 
Watts Series Picture I/P Voltage Safety Features  Isolation:1600VDC
  Operating Temperature:
          -40°C~+80°C Down Load ST60 Series SPC.
     48V (18-72V) VDC CE  •Smaller Size
 •4:1 Wide Input Range
 •High Efficiency
 •Remote ON/OFF Control
 •Protections: Over Voltage /
    Over Temperature /
    Short Circuit all by Auto-recovery
60 W ST60 O/P Voltage Dimension
Single:12,15,24   52.8 x 27.5 x 13.5 mm
  2.08 x 1.08 x 0.53 Inches